← All tips & tricks

Will Watches / The beginner build hub

Build your
first watch.

Your starting point for an NH35 watch build. Watch the series, check your parts, prepare your bench, and work through the assembly one careful stage at a time.

Watch the series ↓
Watch first. Build second.

This is assembly using a complete movement, not a movement-servicing course. The written notes are a companion reference, not a transcript of each clip. Exact fit and procedures depend on your chosen parts; stop and investigate resistance instead of adding force.

The build series / Seven videos

Follow along with Will.

The videos below follow the same sequence as the original homepage collection. Open any clip on TikTok if the embedded player is unavailable.

Before ordering

Parts that work together.

Choose the whole combination before buying individual pieces. These are general supply categories; confirm dimensions and compatibility with the seller for the exact products.

  • NH35 movement

    Buy the specified caliber and variant from a seller who identifies it clearly. Test winding, setting, date operation, and running before fitting anything.

  • Case, crown, and movement holder/spacer

    Choose a case explicitly made for your movement and confirm the correct spacer, crown, stem, case back, crystal, and seals are included or available.

  • Dial

    Confirm the diameter accepted by the case, dial-foot positions for the movement and crown position, and alignment of the date window. “NH35 compatible” alone does not settle every fit question.

  • Hour, minute, and seconds hands

    Use a set specified for NH35 with suitable lengths and height clearance for your dial and case. Similar-looking hands are not necessarily interchangeable.

  • Correct stems, including a spare

    Use stems specified for the caliber. The final length depends on the particular case and crown; there is no universal cut length.

  • Strap or bracelet and spring bars

    Match the case’s lug width and spring-bar requirements. A fitted-end bracelet also needs the correct end-link shape for that case.

A matching movement name is only the beginning.

Case size is not dial size. Crown position affects dial and date alignment. Hand length and hand height are separate checks. Ask suppliers to confirm the complete combination in writing before ordering.

Prepare the bench

The tools for this build.

  • Clean, well-lit bench

    Padded mat, adjustable light, loupe, covered parts tray, and a dust cover.

  • Movement support

    An NH35-compatible holder suitable for hand fitting. A soft cushion alone is not a substitute for correct support beneath the movement.

  • Hand-fitting tools

    Hand-setting tools with suitable tips, a dial protector, and hand removers for corrections.

  • Clean handling

    Fine non-marring/antimagnetic tweezers, finger cots, a hand air blower, and clean microfiber cloths. Avoid touching the dial or hand surfaces.

  • Stem-fitting tools

    Pin vise, suitable cutters, fine file, calipers, and a fine marker. Keep filing debris away from the movement.

  • Case and strap tools

    The case-back tool appropriate to your case, case holder where needed, spring-bar tool, and bracelet-sizing tools if required.

Explore the complete tools & supplies guide →

A written companion

Five stages. Take your time.

01 / Plan

Choose a compatible combination

Start with the case and verify the entire parts combination before ordering. Confirm crown position, spacer, dial diameter, date-window alignment, hand lengths, and available height. For a first build, a documented matching set reduces uncertainty.

Checkpoint: every part has a confirmed fit, not merely a similar product photograph.

02 / Prepare

Inspect before assembly

Lay out and identify the parts. Check for shipping damage, dust, bent dial feet, and missing seals or stems. Test the movement while it is still easy to return or replace. Watch the series before starting and use the technical documentation for the actual caliber.

Checkpoint: the movement operates normally and all essential parts and tools are present.

03 / Assemble

Fit the dial and hands carefully

Support the movement properly and fit the dial using the mounting method intended for your components. Establish the date-change reference by advancing the hands clockwise before aligning the hour and minute hands at midnight. Fit one hand at a time, using the correct tip and controlled pressure. View the hand stack from the side and check clearance through a complete cycle. The seconds-hand tube must be aligned with its pinion before seating; more force will not correct misalignment.

Checkpoint: the dial is secure, hands align at 12, the date changes around midnight, and no hand touches the dial, another hand, or the crystal.

04 / Case

Seat the movement and fit the stem

Remove loose dust with a hand blower and inspect under angled light before casing. Seat the movement with the correct spacer and retention method. Identify the stem-release point from the NH35 technical guide: use the normal crown position for removal and only light pressure on the designated lever. Do not press an unidentified screw or force a reluctant stem. Fit the crown and stem to your case by measuring, removing a small amount at a time, and finishing the cut threads away from the movement. Test each crown position and, where fitted, screw-down engagement.

Checkpoint: the movement is secure, the crown winds and sets correctly, and the stem causes no binding or unwanted pressure.

05 / Finish

Inspect, close, and test

Inspect for dust, fingerprints, hand contact, and a trapped or displaced seal. Close the case with the correct tool and the case maker’s procedure. Fit the strap or bracelet and check that both spring bars are seated securely. Observe operation, date change, and timekeeping over the following days. A case’s advertised depth rating does not establish the completed build’s water resistance; arrange appropriate testing before water exposure.

Checkpoint: functions work after closure, hands clear the crystal, the strap is secure, and water resistance remains unclaimed until verified.

Pause and check

Common beginner problems.

The dial does not fit the case.

Stop before trimming anything. Recheck the case’s supported dial diameter, rehaut opening, spacer, and dial-foot/crown-position combination with the suppliers.

The seconds hand will not seat.

Inspect alignment, hand-tube condition, movement support, and compatibility under magnification. Do not keep pressing. A bent hand or damaged pinion may need replacement or a watchmaker.

The watch stops at the same time.

Check for hand-to-hand, hand-to-dial, or hand-to-crystal contact. Do not assume magnetism or start regulating the movement to solve a mechanical obstruction.

The date changes at noon.

The hand alignment may be 12 hours out relative to the date cycle. Re-establish the date-change reference and correct the hands with suitable removal and setting tools.

The crown does not engage correctly.

Recheck stem length, crown compatibility, and movement seating. A short stem generally needs replacement. Do not force the crown or use the case back to press the movement into place.

There is dust under the crystal.

Use a clean workspace and hand blower during a controlled reopening. Do not blow with your mouth, spray canned propellant, or rub the dial to chase a speck.

Can I use a no-date dial or another NH movement?

A no-date dial can conceal the NH35 date display but leaves the movement’s date-setting position. Other NH calibers may require different dial openings, hands, clearance, or parts. Verify the complete combination before substituting.

Before the wrist shot

Your build checklist.

Tick as you go. Checkmarks are temporary and reset on reload.

Technical reference: TMI Download / Support. Select NH35 for its specification sheet, technical guide, and operation manual. Use the current documentation for your movement variant and the case supplier’s fitting instructions.

Keep building your knowledge

From the bench.